High Myopia Corrected with ACR-128 Phakic Lens Implant: Long-term Predictability and Stability
Keywords:
high myopia, phakic lens, predictability, stabilityAbstract
Objective: Determine the predictability and long-term stability of the ACRIOL 128 phakic lens implant for the correction of high myopia.
Method: A descriptive, observational, retrospective longitudinal study was carried out in 33 patients (63 eyes) with ACRIOL-128 lens implantation, in the Refractive Surgery Service of the Cuban Institute of Ophthalmology “Ramón Pando Ferrer” between 2023 and 2024. They were analyzed. surgical variables such as calculated and implanted lens power; biometric and refractive, as well as the predictive error, which allowed predictability and stability to be determined.
Results: Axial length increased in the right eye (RE) by 0.29 ± 0.66 millimeters and 0.25 ± 0.49 in the left eye (LE). The keratometric cylinder decreased, so the induced astigmatism was -0.48 ±0.69 in RE and -0.40 ±0.80 in LE.
The average predictive error was -0.66 ± 0.93 in RE and -0.74 ±0.96 in LE. The predictability index was 83.87% and 54.84% in RE and 81.25% and 53.12% in LE for ±1.0 diopters and ±0.5 diopters respectively.
Conclusions: The implantation of ACRIOL-128 anterior chamber phakic lenses with angular support for the correction of high myopia is a predictable and stable treatment, without induced astigmatism and with a tendency towards long-term hypocorrection; given by the increase in axial length.
Downloads
References
1. Cavazos-Salias CG, Montemayor-Saldaña N, Salum-Rodríguez L, Villarreal-Del Moral JE, Garza-Leon M. Prevalencia de miopía y factores de riesgo asociados en estudiantes de medicina en Monterrey. Rev Mex Oftalmol. 2019;93(5):246-53. DOI: 10.24875/rmo.m19000084
2. Feng Zhan G, Du L, Pérez Hernández G, Pérez Suárez RG, Guerra Almaguer M. Factores asociados a la prevalencia de la miopía mundial y su impacto social. Rev Cubana Oftalmol. 2021 [acceso 15/01/2025];34(4): Disponible en: http://scielo.sld.cu/scielo.php?script=sci_arttext&pid=S0864-21762021000400012&lng=es
3. Holden BA, Fricke TR, Wilson DA, Jong M, Naidoo KS, Sankaridurg P, et al. Global Prevalence of Myopia and High Myopia and Temporal Trends from 2000 through 2050. Ophthalmology. 2016;123(5):1036-42. DOI: 10.1016/j.ophtha.2016.01.006
4. Rey-Rodriguez DV, Moreno-Montoya J, Álvarez-Peregrina C. Prevalence of Myopia in America: A Systematic Review and Meta-Analysis. Cienc Tecnol Para Salud Vis Ocul. 2021;19(1):49-58. DOI: 10.19052/sv.vol19.iss1.6
5. Wolffsohn JS, Whayeb Y, Logan NS, Weng R, the International Myopia Institute Ambassador Group*. IMI—Global Trends in Myopia Management Attitudes and Strategies in Clinical Practice—2022 Update. Investig Opthalmology Vis Sci. 2023;64(6):6. DOI: 10.1167/iovs.64.6.6
6. Tovar Bravo ND, Cando Collaguazo DB. Incidencia de Miopía en pacientes de edad adulta del Instituto de Oftalmología Almagro Quito, 2020 [bachelor Thesis]. [Quito]: Universidad Metropolitana; 2023 [acceso 15/01/2025]. Disponible en: https://repositorio.umet.edu.ec/handle/
7. Hernández Silva JR. Facoemulsificación; La Habana: Editorial Ciencias Médicas; 2022. Capítulo 32, Lente intraocular fáquica y cirugía refractiva. p: 509-21 [acceso 15/01/2025] Disponible: en: http://www.bvscuba.sld.cu/libro/facoemulsificacion
8. Lisa Fernández C, Alió Del Barrio J, Alvarez-Rementería Capelo L, Cano Ortiz A, Castaño Manotas A, Fernández-Vega Cueto L, et al. State of refractive surgery with Visian ICL posterior chamber phakic lens in Spain. Arch Soc Espanola Oftalmol. 2023;98(2):98-104. DOI: 10.1016/j.oftale.2022.06.018.
9. Cárdenas Díaz T, Qi Li F, Pérez Suárez R, Cruz Izquierdo D, Monteagudo Hernández K, Cabrera Ruiz Y. Resultados visuales en la corrección de la alta miopía con implante de lente fáquica ACR-128. Rev Cuba Oftalmol. 2019 [acceso 15/01/2025];32(2). Disponible en: http://scielo.sld.cu/pdf/oft/v32n2/1561-3070-oft-32-02-e611.pdf
10. Cárdenas Díaz T, Li F, Guerra Almaguer M, Fumero González F, Sánchez Acosta L, Torres Gómez O. Efecto de la lente fáquica ACR-128 sobre la tensión ocular y el endotelio corneal en las altas miopías. Rev Cubana Oftalmol. 2018 [acceso 15/01/2025];32(2). Disponible en: https://revoftalmologia.sld.cu/index.php/oftalmologia/article/view/612
11. Van der Heijde GL, Fechner PU, Worst JG. [Optical consequences of implantation of a negative intraocular lens in myopic patients]. Klin Monatsbl Augenheilkd. 1988;193(1):99-102. DOI: 10.1055/s-2008-1050231
12. Li F, Cárdenas Díaz T, Guerra Almaguer M, Pérez Suárez RG. Calidad de vida y visual en pacientes con implante de lente intraocular fáquico. Rev Cuba Oftalmol. 2020 [acceso 15/01/2025];33(3). Disponible en: http://scielo.sld.cu/pdf/oft/v33n3/1561-3070-oft-33-03-e863.pdf
13. Hernández Silva JR. Facoemulsificación. La Habana: Editorial Ciencias Médicas; 2022 Capítulo 18 Ajuste refractivo con láser de excímero en la cirugía del cristalino. p: 271-90 [acceso 15/01/2025] Disponible en: http://www.bvscuba.sld.cu/libro/facoemulsificacion
14. Asociación Médica Mundial. Declaración de Helsinki de la Asociación Médica Mundial: Principios éticos para la investigación médica en la que participan seres humanos. JAMA. 2025;333(1):71–4. DOI: 10.1001/jama.2024.21972i
15. Amro M, Chanbour W, Arej N, Jarade E. Third- and fourth-generation formulas for intraocular lens power calculation before and after phakic intraocular lens insertion in high myopia. J Cataract Refract Surg. 2018;44(11):1321-5. DOI: 10.1016/j.jcrs.2018.07.05
16. Artells de Jorge N. Estudio de las modificaciones biométricas tras implantación de lente intraocular fáquica [tesis de Fin de Máster UVa]. [Valladolid]: Universidad de Valladolid. Instituto Universitario de Oftalmobiología Aplicada (IOBA); 2019 [acceso 15/01/2025]. Disponible en: https://uvadoc.uva.es/handle/10324/19496
17. Cakir I, Sonmez O, Pehlivanoglu S, Cakir GY, Yildiz BK, Yildirim Y, et al. Long-term results of a new posterior chamber phakic intraocular lens in patients with high myopia: 5-year results. J Cataract Refract Surg. 2023;49(4):409-15. DOI: 10.1097/j.jcrs.0000000000001110
18. Kohnen T, Maxwell A, Holland S. Correction of moderate to high myopia with a foldable, angle-supported phakic intraocular lens: results from a 5-year open-label trial. Ophthalmology. 2016;123(5):1027-35. DOI: 10.1016/j.ophtha.2015.12.028
19. Yang R, Zhao S. AcrySof phakic angle-supported intraocular lens for the correction of high to extremely high myopia: one-year follow-up results. Int J Ophthalol. 2012;5(3):360-5. DOI: 10.3980/j.issn.2222-3959.2012.03.21
20. Choi JH, Lim DH, Nam SW, Yang CM, Chung ES, Chung TY. Ten-year clinical outcomes after implantation of a posterior chamber phakic intraocular lens for myopia. J Cataract Refract Surg. 2019;45(11):1555-61. DOI: 10.1016/j.jcrs.2019.06.015
21. Pérez-Santonja JJ, Alió JL, Jiménez-Alfaro I, Zato MA. Surgical correction of severe myopia with an angle-supported phakic intraocular lens. J Cataract Refract Surg. 2000;26(9):1288-302. DOI: 10.1016/s0886-3350(00)00543-5
22. Sánchez-Ventosa Á, Cano-Ortiz A, González Cruces T, Villalba González M, Membrillo A, Villarrubia A. Analysis after posterior chamber phakic intraocular lens implantation: 17- to 19-year follow-up study. J Cataract Refract Surg. 2024;50(8):816-21. DOI: 10.1097/j.jcrs.0000000000001469.
23. Güell JL, Velasco F, Malecaze F, Vázquez M, Gris O, Manero F. Secondary Artisan–Verysise aphakic lens implantation. J Cataract Refract Surg. 2005;31(12):2266-71. DOI: 10.1016/j.jcrs.2005.06.047
Downloads
Published
How to Cite
Issue
Section
License
Copyright (c) 2025 Revista Cubana de Oftalmología

This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.
El contenido de la revista se encuentra accesible sin costo alguno. Está protegido por los términos de la Licencia de Creative Commons Reconocimiento-NoComercial 4.0 Internacional