ACRIOL-128 Phakic Lens Implant for the Correction of High Myopia: Long-term Safety

Authors

Keywords:

high myopia, ; phakic lens, safety

Abstract

Objective: To determine the safety of the ACRIOL 128 phakic lens implant for the correction of high myopia in the long term.

Methods: Descriptive, observational, retrospective longitudinal study with 33 patients (63 eyes) with ACRIOL-128 lens implants at the Refractive Surgery Service of the Ramón Pando Ferrer Cuban Institute of Ophthalmology between 2023 and 2024. Safety was determined through the variables of best-corrected visual acuity, ocular tension, parameters, and endothelial cell loss, as well as lens-cornea and lens-crystalline distance, complications, and treated fundoscopic alterations.

Results: The safety index was 1.35 in the right eye and 1.26 in the left eye. Ocular tension was normal. Endothelial cell loss was 11.70% and 11.87% in the right and left eyes, respectively. The most frequent complication was pupil ovalization in 19.35% of the right eyes and 18.75% of the left eyes. The anatomical relationship of the phakic lens with the structures of the anterior segment was risk-free. Fundoscopic alterations (circumpapillary atrophy, pigment epithelium atrophy, and choroidal atrophy) increased.

Conclusions: The implantation of ACRIOL-128 phakic lenses for the correction of high myopia is a safe long-term technique with good visual acuity and normal intraocular pressure. In addition, it is a procedure that is well tolerated by the corneal endothelium, with low endothelial cell loss, few complications, lens position without risk to the anterior segment structures, and fundoscopic alterations compatible with high myopia.

Downloads

Download data is not yet available.

References

1. Espino García A. Miopía Alta: definición, comorbilidad y corrección refractiva. Revisión bibliográfica. 2019 [acceso 15/01/2024]. Disponible en: https://uvadoc.uva.es/handle/10324/38795

2. Almanzar Brito D. Catarata secundaria al implante de lente intraocular fáquica ICL en cámara posterior [tesis doctoral]. [España]: Universidad de Oviedo; 2017 [acceso 15/01/2025]. Disponible en: https://digibuo.uniovi.es/dspace/handle/10651/43852

3. Rey-Rodríguez DV, Álvarez-Peregrina C, Moreno-Montoya J. Prevalencia y factores asociados a miopía en jóvenes. Rev Mex Oftalmol. 2017;91(5):223-8. DOI: 0.1016/j.mexoft.2016.06.007

4. Ahmed ZA, Alrasheed SH, Alghamdi W. Prevalence of refractive error and visual impairment among school-age children of Hargesia, Somaliland, Somalia. East Mediterr Health J. 2020;26(11):1362-70. DOI: 10.26719/emhj.20.077

5. Martínez-Plaza E, López-Miguel A, Holgueras A, Barraquer RI, Alió JL, Maldonado MJ. Lentes intraoculares fáquicas: recientes avances e innovaciones. Arch Soc Esp Oftalmol. 2020 [acceso 15/01/2025];95(4):178-87. Disponible en: https://www.sciencedirect.com/science/article/abs/pii/S2173579420300396

6. Rizk I, Al-hessy A, El-Khouly S, Sewelam A. Visual performance after implantation of two types of phakic foldableintraocular lenses for correction of high myopia. Int J Ophthalmol. 2019;12(2):284-90. DOI: 10.18240/ijo.2019.02.16

7. Wu Q, Li Y, Tang L, Wu L, Wang C. Comparison of rigid versus foldable iris-fixed phakic intraocular lens implantation for high myopia: a systematic review and meta-analysis. Medicine 2020;99(6):e19030. DOI: 10.1097/MD.0000000000019030

8. Hernández Silva JR. Facoemulsificación; La Habana: Editorial Ciencias Médicas; 2022. Capítulo 32, Lente intraocular fáquica y cirugía refractiva. p: 509-21 [acceso 15/01/2025] Disponible: en: http://www.bvscuba.sld.cu/libro/facoemulsificacion

9. Cárdenas Díaz T, Qi Li F, Guerra Almaguer M, Fumero González F, Sánchez Acosta L, Torres Gómez O. Efecto de la lente fáquica ACR-128 sobre la tensión ocular y el endotelio corneal en las altas miopías. Rev Cubana Oftalmol. 2018 [acceso 15/01/2025];32(2). Disponible en: https://revoftalmologia.sld.cu/index.php/oftalmologia/article/view/612

10. Cárdenas-Díaz T, Li F, Vargas-Verga J, González-Ortega M, Guerra-Almaguer M. Seguridad del implante de lente fáquica ACR-128 tras un año de seguimiento. Revista Cubana de Investigaciones Biomédicas. 2021 [acceso 15/01/2025];40(4). Disponible en: http://www.revibiomedica.sld.cu/index.php/ibi/article/view/1319

11. Hernández Silva JR. Facoemulsificación. La Habana: Editorial Ciencias Médicas; 2022 Capítulo 18. Ajuste refractivo con láser de excímero en la cirugía del cristalino. p: 271-90 [acceso 15/01/2025] Disponible en: http://www.bvscuba.sld.cu/libro/facoemulsificacion

12. Asociación Médica Mundial. Declaración de Helsinki de la Asociación Médica Mundial: Principios éticos para la investigación médica en la que participan seres humanos. JAMA. 2025;333(1):71–4. DOI: 10.1001/jama.2024.21972i

13. Choi JH, Lim DH, Nam SW, Yang CM, Chung ES, Chung TY. Ten-year clinical outcomes after implantation of a posterior chamber phakic intraocular lens for myopia. J Cataract Refract Surg. 2019 [acceso 15/01/2025];45(11):1555. DOI: 10.1016/j.jcrs.2019.06.015

14. Lisa Fernández C, Alió Del Barrio J, Alvarez-Rementería Capelo L, Cano Ortiz A, Castaño Manotas A, Fernández-Vega Cueto L, et al. State of refractive surgery with Visian ICL posterior chamber phakic lens in Spain. Arch Soc Española Oftalmol. 2023;98(2):98-104. DOI: 10.1016/j.oftale.2022.06.018. Epub 2022 Sep 15.

15. Cakir I, Sonmez O, Pehlivanoglu S, Cakir GY, Yildiz BK, Yildirim Y, et al. Long-term results of a new posterior chamber phakic intraocular lens in patients with high myopia: 5-year results. J Cataract Refract Surg. 2023;49(4):409. DOI: 10.1097/j.jcrs.0000000000001110

16. Pérez-Santonja JJ, Alió JL, Jiménez-Alfaro I, Zato MA. Surgical correction of severe myopia with an angle-supported phakic intraocular lens. J Cataract Refract Surg. 2000;26(9):1288-302. DOI: 10.1016/s0886-3350(00)00543-5

17. Sánchez-Ventosa Á, Cano-Ortiz A, González Cruces T, Villalba González M, Membrillo A, Villarrubia A. Analysis after posterior chamber phakic intraocular lens implantation: 17- to 19-year follow-up study. J Cataract Refract Surg. 2024;50(8):816. DOI: 10.1097/j.jcrs.0000000000001469

18. Yildirim Y, Çakmak S, Sucu ME, Kepez Yildiz B, Kirgiz A, Akbas YB, et al. Comparative study of small-incision lenticule extraction and phakic intraocular lens implantation for the correction of high myopia: 6-year results. J Cataract Refract Surg. 2021;47(2):221 DOI: 10.1097/j.jcrs.0000000000000418

19. Alió JL, Piñero D, Bernabeu G, Galal A, Vargas JM, Ismail MM. The Kelman Duet phakic intraocular lens: 1-year results. J Refract Surg Thorofare NJ 1995. 2007;23(9):868-79. DOI: 10.3928/1081-597X-20071101-02

20. Güell JL, Velasco F, Malecaze F, Vázquez M, Gris O, Manero F. Secondary Artisan–Verysise aphakic lens implantation. J Cataract Refract Surg. 2005;31(12):2266-71. DOI: 10.1016/j.jcrs.2005.06.047

21. López Hernández SM, Rodriguez Rivero D, González Duque Y, Martín Perera Y, Castro Cárdenas K. Variación del endotelio corneal en pacientes operados de alta miopía con implante de lentes fáquicas. Rev Cuba Oftalmol. 2013 [acceso 15/01/2025];360-8 Disponible en: http://scielo.sld.cu/scielo.php?script=sci_arttext&pid=S0864-21762013000300002&lng=es

22. Puente Bustillo S. Prevención de la Miopía Patológica. [tesis de master]. [España]: Universidad de Valladolid; 2023 [acceso 15/01/2025]. Disponible en: https://uvadoc.uva.es/handle/10324/62634

Published

2025-06-27

How to Cite

1.
Hechavarría Polanco S de la C, Gonzáles Gonzáles L, Castillo Nuñez R, Rodríguez Caro Y, Cárdenas Díaz T. ACRIOL-128 Phakic Lens Implant for the Correction of High Myopia: Long-term Safety. Rev Cubana Oftalmol [Internet]. 2025 Jun. 27 [cited 2025 Dec. 8];38. Available from: https://revoftalmologia.sld.cu/index.php/oftalmologia/article/view/2019

Issue

Section

Investigaciones